Specifications

PT-RZ570
 
PT-RZ570
Power supply AC 100–240 V, 50/60 Hz
Power consumption*1 500 W (520 VA, 100 V AC) (0.5 W with Standby Mode set to Eco*2, 10 W with Standby Mode set to Normal, 22 W with Standby Mode in Audio Setting set to ON and Quick Startup function disabled, 50 W with Quick Startup function enabled); 375 W (Normal Mode), 350 W (Eco or Silent Mode), 40 W (shutter closed) [Picture Mode: Standard, Dynamic Contrast: ON]
DLP™ chip  
Panel size 17.0 mm (0.67˝)
diagonal (16:10 aspect ratio)
Display method DLP™ chip x 1, DLP™ projection system
Pixels 2,304,000 (1920 x 1200) pixels
Lens 2.0 x manual zoom (throw ratio: 1.46–2.94:1), manual focus, F 2.0–3.4, f 21.5–43.0 mm
Light source Laser diode (Class 1) (Class 3R for North America), Light source life: 20,000 hours at half luminance (Normal Mode, Temperature: 35 °C [95 °F], altitude: 700 m [2,297 ft], Dust: 0.15 mg/m3)
Screen size (diagonal) 1.02–7.62 m (40–300˝), 16:10 aspect ratio
Brightness 5,400 lm (Center)*4 / 5,200 lm*3*4
Contrast*3 20,000:1 (Full On/Full Off, Dynamic Mode and Dynamic Contrast: ON)
Resolution 1920 x 1200 pixels
Supported RGB signal XGA–WUXGA
Supported video signal NTSC/PAL/SECAM, 480p/i, 720p, 1080p/i
Optical axis shift
(from center of screen)
 
Vertical -44 %, +64 % (manual)
Horizontal -27 %, +34 % (manual)
Keystone correction range Vertical: ±40 °, horizontal: ±20 °,
Up to a total of ±60 ° during simultaneous horizontal and vertical correction
Installation Ceiling/floor, front/rear, 360-degree free installation
Cabinet materials Molded plastic
Dimensions (W x H x D) 498 x 168*5 x 492 mm (19 5/8˝ x 6 5/8˝*5 x 19 3/8˝)
Weight*6 Approximately 16.3 kg (35.9 lbs)
Operation noise*3 28 dB (Silent Mode), 33 dB (Normal/Eco Mode)
Operating environment Operating temperature: 0–45°C (32–113°F)*7, operating humidity: 10–80 % (no condensation)
Applicable software Logo Transfer Software, Multi Monitoring & Control Software, Early Warning Software
   
Terminals PT-RZ570

*1 Operating temperature: 25 °C (77 °F), altitude: 700 m (2,297 ft), IEC627087: 2008 Broadcast Content.

*2 When Standby Mode is set to Eco, network functions such as power on over LAN will not operate.

*3 Measurement, measuring conditions, and method of notation all comply with ISO 21118 international standards.

*4 With operation mode set to Normal.

*5 With legs at shortest position.

*6 Average value. May differ depending on the actual unit.

*7 The operating environment temperature should be between 0 °C (32 °F ) and 40 °C (104 °F ) when the projector is used at altitudes between 1,400 m (4,593 ft) and 4,200 m (13,780 ft) above sea level. When [PROJECTOR SETUP] menu > [ECO MANAGEMENT] > [OPERATING MODE] is set to [ECO] or [SILENT], the projector cannot be used at an altitude of 2,700 m (8,858 ft) or higher above sea level. When using the projector at an altitude lower than 2,700 m (8,858 ft) above sea level and the operating environment temperature is 35 °C (95 °F) or higher, light output may be reduced to protect the projector. When using the projector at an altitude between 2,700 m (8,858 ft) and 4,200 m (13,780 ft) and the operating environment temperature is 25 °C (77 °F) or higher, light output may be reduced to protect the projector.